Galvalibs technical specifications

  • Chemistry

    • Soluble aluminum

      0.005% to 10.0%

    • Soluble magnesium

      0.005% to 6.0%

    • Soluble iron

      0.008% to 2.0%

    • Soluble silicon

      0.002% to 12.0%*

    • Fe dross

      0.002% to 0.1%**

    • Al dross

      0.002% to 0.1%**

  • Chemistry precision

    • Standard deviation

      0.5%

    • 30-day drift

      1%

  • Pot level measurement precision

    • Standard deviation precision

      ±0.5 mm

  • Consummables

    • Grade 4.8 argon or better (0.75 to 1.0 lpm)
    • Industrial grade compressed air (10 cfm)
  • Maintenance

    • Laser di water refill
    • Laser di water filter
    • Lance inspection
    • Compressed air filter replacement
    • Annual probe maintenance
  • Dimensions and weight

    • Probe

      508 mm X 127 mm X 203 mm
      20 in X 5 in X 8 in
      18 kg / 40 lb

    • Controller

      812 mm X 355 mm X 1143 mm
      32 in X 14 in X 45 in
      113 kg / 250 lb

    • Cable conduit

      13.5 m / 45 ft (length)
      75 kg / 165 lb

* Silicon above 3 wt% applies to aluminizing only.
** Dross measurements are calibrated using excess Fe and Al in manual sampling.